PC2

 

 

 

TECHNICAL PARAMETER   

               20/150      kg      Maximum capacity                                              (Emax)
G3  (GP)    Accuracy class according to OIML R60
3000 n.a.   Maximum number of verification intervals                 (nls) 
Emax/10 000 n.a   Minimum load cell verification inteval 
   ± 0.0140   ± 0.0400    %R0/10°C Tempereture effect on minimum dead load output    (TC0
     ± 0.0100      ± 0.0200      %R0/10°C  Temperature effect om sensitivity                         (TCR0
      ± 0.0200     ± 0.0500    %R0 Combined error 
    ± 0.0166    ± 0.0400    %R0 Non-linearity 
    ± 0.0166    ± 0.0400    %R0 Hysteresis 
    ± 0.0166   ± 0.0600  %R0 Creep error (30 minutes) / DR 
2 ± 5% mV/V Rated Output                                                     (R0)      
± 5 %R0 zero balance
5~15 V Excitation voltage
110 ± 50  Ω Input resistance                                                   (RLc)
960 ± 50  Ω Output resistance                                                (R out
≥ 5000   Insulation resistance (100 V DC)                  
200    %Emax Safe load limit                                                     (Elim
300     %Emax Ultimate load 
100   %Emax Safe side load 
600x600 for 20kg / 1000x1000 for 150kg mm Maximum platform sixze; Loading according to OIML R76
250 for 20kg / 400 for 150kg mm Maximum off center distance at Maximum capacity
-10~+40   °C compensated temperatue range 
-40~+80(ATEX-40~+60) °C Operation temperature range
stainless steel 17-4 PH(1.4548)   Load cell material
cable entry sealed by a glass to metal header   Sealing
IP68(up to 2 m watwr depth) / IP69k   Protection according EN 60 529

 

 

 

Connection


Ref- ref+ shield Sig - Sig + Exc- Exc +
    Yellow   Red White  Black  Green 

 

  

 

 


File To Download


 