PC46

 

 

 

TECHNICAL PARAMETER   

     250         50/100/150/200/250      kg      Maximum capacity                                              (Emax)
  C4   C3   (GP)    Accuracy class according to OIML R60
4000 3000  n.a.   Maximum number of verification intervals                 (nls) 
Emax/12500 Emax/7500 n.a.   Minimum load cell verification inteval 
   ± 0.0112   ± 0.0187   ± 0.0400   %R0/10°C Tempereture effect on minimum desd load output (TC0
  ± 0.0800     ± 0.0100    ± 0.0200    %R0/10°C Temperature effect om sensitivity                       (TCR0
 ± 0.0180    ± 0.0200    ± 0.0500    %R0 Combined error 
 ± 0.0125   ± 0.0166      ± 0.0400    %R0 Non-linearity
 ± 0.0125   ± 0.0166    ± 0.0400    %R0 Hysteresis 
± 0.0125 ± 0.0166 ± 0.0600  %R0 Creep error (30 minutes) / DR 
Emax/25000    Emax/15000    n.a.   Min.load cell verification interval                      (Vmin opt) 
± 0.0056 ± 0.0093 n.a.  %R0/10°C Temp .effect on min.dead load output                (TC0 opt)
2 ± 10% mV/V Rated Output                                                     (R0)      
± 5 %R0 zero balance
5-15 V Excitation voltage
413 ± 20 Ω Input resistance                                                   (RLc)
350 ± 25 Ω Output resistance                                                (R out
≥ 5000   Insulation resistance (100 V DC)                  
150    %Emax Safe load limit                                                     (Elim
300     %Emax Ultimate load 
100   %Emax Safe side load 
400x400 mm Maximum platform sixze; Loading according to OIML R76
150 mm Maximum off center distance at Maximum capacity 
-10~+40   °C compensated temperatue range 
-20~+65(ATEX-20~+60) °C Operation temperature range
stainless steel 17-4 PH(1.4548)   Load cell material
Aluminium   Sealing
IP67   Protection according EN 60 529

 

 

 

Connection


Ref- ref+ shield Sig - Sig + Exc- Exc +
    Yellow   Red White  Black  Green 

 

  

 

 


File To Download


 

PC46 DataSheet   ATEX Operation Manual
PC46-Test Certificate